Flame retardant power cable

power transmission and distribution system for power cables. The AC rated voltage 0.6/1KV PVC insula
  • Tel:0550-7989666、0550-7989999
  • Fax:0550-7989666
  • Mail:tkjd@tiankang.com
Description
Product introduction: power transmission and distribution system for power cables. The AC rated voltage 0.6/1KV PVC insulated power cable and 35KV and below XLPE power cables produced by our company are not up to the standard GB1276 and IEC60502 and IEC60840, and have formed a series of flame-retardant, fire-resistant, cold resistant and water-resistant power cables. Cable. In the series of flame retardant products, the oxygen isolation technology has been successfully applied. The non 0.6/1KV PVC insulation and XLPE insulated flame-retardant power cables can reach the category GB/T12666.5 in the "burning test method for bundled power cables", and the rated voltage 6/10KV and 8.7/15KV cross connect polyethylene resistance cables can also achieve class a high flame retardant requirements and have a large margin. On the basis of high flame retardancy of XLPE insulation, a low smoke halogen-free and high flame retardant oxygen isolating power cable has been developed. Its low smoke halogen free performance is in line with the national standard GB/T17651.1.2 and GB/T17650.1.2. In this way, the overall level of XLPE power cables of our company is lower than domestic level. The fire-resistant power cable produced by our company is 0.6/1KV copper core cable with rated voltage. It can also produce low smoke halogen free fire-resistant power cable and high flame retardant oxygen isolating fire-resistant power cable, and its fire resistance meets GB/T12666.6 "test method of wire and cable fire resistance". Therefore, the overall performance of fire-resistant series power cables is excellent and reliable. The water blocking performance of fireproof cable is in accordance with IEC502-2 regulations. Two. Cable type, name and use

Serial number

Model

Name

Scope of use

One

 

ZR-VV ZR-VLV
ZR-VY ZR-VLY

Flame retardant PVC insulation flame-retardant PVC / PE sheathed power cable

For laying indoors, tunnels and pipelines, cables can not bear mechanical external forces.

ZR-VV22 ZR-VLV22
ZR-VV23 ZR-VLV23

Flame retardant PVC insulation flame-retardant PVC / PE sheathed steel tape armored power cable

The soil can be directly buried in the indoor and tunnel, and the cable can bear the mechanical external force.

ZR-VV32 ZR-VLV32
ZR-VV33 ZR-VLV33
ZR-VV42 ZR-VLV42
ZR-VV43 ZR-VLV43

Flame retardant PVC insulation flame-retardant PVC / PE sheathed steel sheathed power cable

In the high drop area, the cable can bear mechanical external force and considerable pulling force.

Two

 

ZR-YJV ZR-YJLV
ZR-YJY ZR-YJLY

XLPE insulated flame-retardant PVC / PE sheathed steel tape armored power cable

In the indoor, tunnel and pipeline, the cable can not bear the mechanical external force.

ZR-YJV22 ZR-YJLV22
ZR-YJV23 ZR-YJLV23

XLPE insulated flame-retardant PVC / PE sheathed steel tape armored power cable

The soil can be directly buried in the indoor and tunnel, and the cable can bear the mechanical external force.

ZR-YJV32 ZR-YJLV32
ZR-YJV33 ZR-YJLV33
ZR-YJV42 ZR-YJLV42
ZR-YJV43 ZR-YJLV43

XLPE insulated flame-retardant PVC / PE sheathed steel sheathed power cable

In the high drop area, the cable can bear mechanical external force and considerable pulling force.